Alvarion BreezeACCESS 900 Manuál s instrukcemi Strana 160

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 324
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 159
2-30
BreezeACCESS Version 4.5 Operations and Administration
Manual Revision: 1.0
High Retransmissions Rate Alarm
Severity: Minor, Major
On Conditions: Minor Severity Alarm:
a. The Retransmissions Current Rate exceeds the
Retransmissions Minor Alarm Threshold, and is
higher than the Retransmissions Average Rate by at
least Retransmissions Minor Alarm Minimum Delta,
-OR-
b. The Retransmissions Current Rate has dropped below
the Retransmissions Major Alarm Threshold but is still
higher than the Retransmissions Minor Alarm
Threshold.
Major Severity Alarm: The Retransmissions Current Rate is
higher than the Retransmissions Major Alarm Threshold.
Off Conditions: a. The Retransmissions Current Rate has dropped below
the Retransmissions Minor/Major Alarm Threshold,
-OR-
b. All alarms were cleared,
-OR-
c. AU Alarms Option was disabled
Possible Problem: a. Transmitter or receiver fault
b. Poor link conditions, strong interference, or an
overloaded network.
Zobrazit stránku 159
1 2 ... 155 156 157 158 159 160 161 162 163 164 165 ... 323 324

Komentáře k této Příručce

Žádné komentáře